9. Inspection and Replacement
9-7
9.7 Replacement Interval and Maintenance of the Key Components
Inverter constitutes a number of electronic parts including semiconductor device. The parts
used in the inverter are subject to change as time elapses for its construction or nature.
Therefore without any replacement of parts, it may cause failure or deterioration in the
performance the inverter. For this reason, it requires regular replacement of the parts.
Name of parts
Standard interval
for replacement
Symptoms
How to Replace and
Countermeasure
Cooling Fan
2 ~ 3 years
Poor Rotation
Replacement into new part
DC Link condenser
5 years
Reduction in
Capacity
Replacement into new part
Control Panel Flat
Condenser
5 years
Reduction in
Capacity
Replacement into new part
Control Board Relay
-
Poor Operation
Replacement into new part
Braking Resistance
-
Reduction in
Capacity
Replacement into new part
Duration of the key components is based on the continuous operation at a rated load.
Therefore the duration is subject to change depending on the service condition and
ambient environment
.