6. Function Description
6-1
Chapter 6
–
Function Description
6.1 Display Group (DIS_[][])
6.1.1 DIS_00 (Motor control status monitoring)
Displayed when Power ON.
Code
Parameter name
Unit
Description
DIS_00
Motor speed
rpm
Actual motor rotating speed displayed in rpm.
Motor control mode
SPD
: Speed control mode
TRQ
: Torque control mode
WEB
: WEB control mode
SLS
: Sensorless control mode
BX
: Emergency stop display
BAT
: Battery-operated mode
Output torque
%
100% = Rated torque of motor
Inverter output current
A
Inverter actual output current displayed
6.1.2 DIS_01 ~ 03 (User display 1, 2, 3)
Select one of the followings each to be displayed in DIS_01, 02 and 03.
Factory default:
DIS_01
=
“
PreRamp Ref
”
,
DIS_02
=
“
DC Bus Volt
”
,
DIS_03=
“
Terminal In
”
Code
Parameter name
LCD display
Unit
Description
DIS_01
~
DIS_03
Ai1 Value ~
Ai3 Value
*
1
Ai1 Value ~
Ai3 Value
%
Displayed as the percentage of multi-function analog
input value
(10V / 100%, 20mA / 100%)
Pre Ramp Reference
PreRamp Ref
rpm Speed reference before Acc./dec. routine
Post ramp reference
PostRamp Ref
rpm Speed reference after Acc./dec. routine
ASR Input Reference
ASR Inp Ref
rpm
Final speed reference input value to ASR (Automatic
Speed Regulator) displayed (Draw and Droop
included)
Motor Rotating Speed
Motor Speed
rpm Actual motor rotating speed
Speed of revolution
about motor estimated
Motor SpdEst
rpm Estimated motor speed of revolution
(in sensorless control mode)
Speed Deviation
Speed Dev
rpm Deviation between speed ref and actual rotating
speed
ASR Output
ASR Out
%
ASR output to rated torque
Torque bias
Torque Bias
%
Torque bias to rated torque
Motor speed
Motor control mode
Output current
Output torque
0.0rpm SPD
Tq
0.0% 0.0A