8
Terminal – menus [Medium Plus/Comfort Plus Electronics]
8.16
Alarm messages
86
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
Error number
Possible cause
Remedy
522021-0
LR>MAX
The total baling force on the machine
has been exceeded
In manual mode:
•
Reduce the target bale channel
flap pressure.
In automatic mode:
•
If the alarm is actuated
frequently, reduce the target
baling force.
522022-0
L>MAX
The baling force on the left bale
channel flap has been exceeded.
522023-0
R>MAX
The baling force on the right bale
channel flap has been exceeded.
522024-7
The lower twine is torn.
•
Check the twine and the twine
tensioner.
522025-1
1
On the upper twine 1…8 the
minimum twine length has not been
reached during knotting.
•
Check the knotter and knotter
triggering.
•
Set the sensor.
522026-1
2
522027-1
3
522028-1
4
522029-1
5
522030-1
6
522031-1
7
522032-1
8
522033-0
1
On the upper twine 1…8 the
maximum twine length has been
exceeded during knotting.
•
Check the knotter and knotter
triggering.
•
Set the sensor.
Содержание 870 HDP
Страница 380: ...FLUFXLW GLDJUDP 1 LJ3DFN EDOHU L 3 LJK 6SHHG 3 ...