Maintenance – electrical system
348
Pos: 155 /Überschriften/Ü berschriften 3/A-E/E/Einstell ung der Sensor en @ 0\mod_1199962173428_78.docx @ 37635 @ 3 @ 1
27.2.1
Adjusting the Sensors
Pos: 156 /BA/War tung/Sensor en/Namursensor d = 08 mm @ 24\mod_1241770312369_78.docx @ 248607 @ 4 @ 1
27.2.1.1
Namur sensor d = 8 mm
a
BP-VFS-088-1
2
1
3
Figure 253:
The dimension between the encoder (2) and the sensor (1) must be "a" = 0,5 mm
.
Setting
• Loosen the nuts on either side of the sensor.
• Turn the nuts until dimension "a" = 0,5 mm
is reached.
• Tighten the nuts again.
Pos: 157 /BA/War tung/Sensor en/Namurs ensor d = 12 mm @ 0\mod_1199962247038_78.docx @ 37654 @ @ 1
Namur sensor d = 12 mm
a
BP-VFS-088-1
2
1
3
Figure 254
The dimension between the encoder (2) and the sensor (1) must be "a" = 2 mm
.
Setting
• Loosen the nuts on either side of the sensor.
• Turn the nuts until dimension "a" = 2 mm
is reached.
• Tighten the nuts again.
Pos: 158 /BA/War tung/Sensor en/Namursensor d = 30 mm a= 5mm @ 0\mod_1199962520100_78.docx @ 37673 @ 4 @ 1