Terminal – menus [Medium Plus/Comfort Plus Electronics]
8
Menu 15 "Settings"
8.15
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
75
BP000-245
Press a bale (2) until ¾ of its length have exited the bale channel (1).
Æ
The signal sheet (3) does not cover the sensor (4). The sensor (4) is unattenuated (there is
no iron in front of the sensor).
ü
The machine is shut down and safeguarded,
.
Check dimension X, measured between the upper edge of the sensor (4) and the edge of
the signal sheet (3).
Æ
If dimension
X=5 mm
, the distance of the sensor is correct.
Æ
If dimension
X is not 5 mm
, adjust the sensor.
Adjustment
Loosen the nuts (5) on both sides of the sensor (4).
Push the sensor (4) upwards until dimension
X=5 mm
.
Measured between the upper edge of the sensor (4) and the edge of the signal sheet (3).
Tighten the nuts (5) (tightening torque = 10 Nm).
In the sensor test check that the sensor (4) is still unattenuated,
.
Æ
The sensor has been adjusted correctly if the sensor test shows that the sensor is not alive.
Æ
If the sensor test shows that the sensor is attenuated, adjust the sensor until the sensor test
shows that the sensor is unattenuated.
BP000-246
Check
Continue pressing the bale (2) until it has completely left the bale channel (1).
Æ
The signal sheet (3) completely covers the sensor (4). The sensor (4) is attenuated (iron).
ü
The machine is shut down and safeguarded,
.
Check dimension X, measured between the signal sheet (3) and the sensor (4).
Содержание 870 HDP
Страница 380: ...FLUFXLW GLDJUDP 1 LJ3DFN EDOHU L 3 LJK 6SHHG 3 ...