Terminal – Menus [Medium/Comfort Version Electronics]
217
No./symbol
Possible cause
Remedy
18
– The 2 positions of the MultiBale
or total bales cannot be set.
– The "MultiBale" sensor has been
incorrectly set.
– No compressed air available.
– Fault on the "MultiBale" valve:
– Jams
– Coil defective
• Correctly set the sensor.
• Check the mechanism in the
area of the knotter triggering.
• Check the electronics in the area
of the "MulitBale" lock.
19
– The "Packer feed" sensor has
been incorrectly set.
• Correctly set the sensor.
20
– The bale ejector was triggered
although the bale chute is still
raised.
• Lower the bale chute.
• Activate the bale ejector.
21
– The "Measure" and "Calibrate"
sensors have been mixed up.
• Swap the plugs of the "Measure"
and "Calibrate" sensors.
22
– The knotter 1…6 is not
functioning properly.
– The "Knotter" sensor has been
incorrectly set.
• Check the knotter and knotter
triggering.
• Correctly set the sensor-
23
24
25
26
27
28
– No grease in the container.
– There is a blockage.
– The pump is not running.
• Top up the grease.
• Clean the central lubrication.
• Check the electrical system and
the pump.
Содержание 870 HDP