Maintenance - hydraulic system
315
Pos: 114 /BA/War tung/Load- Sensi ng/Großpackenpresse/Not-Handbetätigung H S Baurei he @ 63\mod_1299838530165_78.docx @ 576700 @ 2 @ 1
21.3
Emergency Manual Activation
The electromagnetic valve block for the In-cab Comfort kitis located at the front on the left under
the side cover next to the electronics box.
In the event the electrical system should fail completely, the valves are equipped with an
<<Emergency manual activation>>.
Comfort Electronics:
• The valves (Y3 to Y8, Y18,Y19 and Y20) are activated by turning in the knurled head screw.
• The valves (Y1,Y2 and Y17) are be activated with the help of a pointed object by pressing in
on the valve.
Pos: 115 /Layout Module /---------------Seitenumbr uch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Содержание 870 HDP