Terminal – Menus [Medium/Comfort Version Electronics]
215
Pos: 85.315 /Ü berschriften/Ü berschriften 3/K- O/L/Logische Al arme @ 185\mod_1379419186279_78.docx @ 1594483 @ 3 @ 1
16.15.2
Logical Alarms
Pos: 85.316 /BA/Info-C enter /Großpackenpresse/Hauptmenüs/Alar mmeldung en/2) Alar mmeldung en Tabelle allgemein 0 - 9 @ 374\mod_1442555491388_78.docx @ 2723075 @ @ 1
No./symbol
Possible cause
Remedy
0
– The twine is torn.
– The twine end has been reached.
• Check the twine and the twine
tensioner.
1
– Blockage in the intake area of the
packer
– The "Packer monitoring" sensor
has been incorrectly set.
• Stop the travelling gear
immediately.
• Reduce the PTO speed until the
blockage has been removed.
• Correctly set the sensor.
2
– The force of pressure on the left
bale channel flap has been
exceeded.
In manual mode:
• Reduce the target bale channel
flap pressure.
In automatic mode:
• If the alarm is actuated
frequently, reduce the target
force of pressure.
3
– The force of pressure on the right
bale channel flap has been
exceeded.
4
– The knotter is not functioning
properly.
– The "Knotter monitoring" sensor
has been incorrectly set.
• Check the knotter and knotter
triggering.
• Correctly set the sensor.
5
– The "Measure" sensor is
defective or has been incorrectly
set.
• Correctly set the sensor.
6
– The "Calibrate" sensor is
defective or has been incorrectly
set.
• Correctly set the sensor.
7
– The flywheel brake is applied.
• Release the flywheel brake.
8
– The shear screw is torn.
• Replace the shear screw.
• Check the needles.
• Check the swivel range of the
needles.
• Check the twine guide.
9
– The bale chute is raised and the
PTO shaft is rotating.
• Lower the bale chute.
Pos: 85.317 /Layout M odul e /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Содержание 870 HDP