8
Terminal – menus [Medium Plus/Comfort Plus Electronics]
8.16
Alarm messages
84
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
Error number
Designation
Icon
521104-5
Voltage group (UB5)
521105-5
Voltage group (UB6)
FMI 6: There is a short circuit or ground fault.
Error number
Designation
Icon
521100-6
Voltage group (UB1)
LOW
521101-6
Voltage group (UB2)
521102-6
Voltage group (UB3)
521103-6
Voltage group (UB4)
521104-6
Voltage group (UB5)
521105-6
Voltage group (UB6)
FMI 11: The cause of the error is unknown.
Error number
Designation
Remedy
521106-11
The supply voltage of the sensors could not
be activated.
LOW
8.16.1.5
Logical errors 522000 – 522099
Error number
Possible cause
Remedy
522000-7
During active lubrication no
lubrication flow was detected.
•
Top up grease.
•
Clean the central lubrication.
•
Check the electrical system and
the pump.
522001-7
The flywheel brake is engaged and
the cardan shaft is rotating.
•
Release the flywheel brake.
522002-7
The starting aid is active while the
flywheel brake is engaged.
522003-0
The slip of the tensioning belt on the
cutting rotor is too great.
•
Remove the crop blockage.
•
Set the sensor.
522004-0
>MAX
The pressure on the belt drive for the
cutting rotor is too great.
•
Check the hydraulics.
•
Check the sensor and replace if
required.
522005-2
The cardan shaft rotates in "road
travel" mode.
•
Switch off the PTO shaft.
•
Switch the operating mode
522006-0
ERROR
The cardan shaft is rotating more
quickly than permitted.
•
Reduce cardan shaft speed.
Содержание 870 HDP