8
Terminal – menus [Medium Plus/Comfort Plus Electronics]
8.15
Menu 15 "Settings"
76
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
Æ
If dimension
X=2-3 mm
, the sensor has been correctly set.
Æ
If dimension
X is not 2-3 mm
, set the sensor.
Adjustment
Loosen the nuts (5) on both sides of the sensor (4).
Turn the nuts (5) until dimension
X=2-3 mm
.
Tighten the nuts (5) (tightening torque = 10 Nm).
In the sensor test check whether the sensor (4) is attenuated,
Æ
The sensor has been adjusted correctly if the sensor test shows that the sensor is alive.
Æ
If the sensor test shows that the sensor is not alive, adjust the sensor until the sensor test
shows that the sensor is alive.
8.15.2
Menu 15-2 "Actuator test"
WARNING
Risk of injury due to non-observance of safety instructions
If the relevant safety routines are not observed, persons may be seriously injured or killed.
The safety routines must be read and observed to avoid accidents,
.
Observe the safety routine "Run actuator test safely",
.
Possible actuators (depending on how the machine is equipped)
An overview of the position of the sensors and actuators is in the circuit diagram,
.
No.
Actuator
Designation
K01
K01
Move in pilot valve
K02
K02
Move out pilot valve
K03
K03
Bale chute valve piston side
K04
Y04
Bale chute valve ring side
K05
K05
Residual bale ejector piston side
K06
K06
Residual bale ejector ring side
K07
K07
Blade cassette valve ring side
K08
K08
Blade cassette valve piston side
K09
K09
Open bale channel flaps