8
Terminal – menus [Medium Plus/Comfort Plus Electronics]
8.16
Alarm messages
80
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
8.16.1.1
General information on error messages
Configuration of an error message
The error message is configured according to the following sample: e.g. error message
"520192-19
KBT
"
520192
19
KBT
SPN (Suspect Parameter
Number) = error number
FMI=type of error,
Icon
Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) and with an appropriate code.
FMI
Meaning
0
The upper limit value was exceeded.
1
The lower limit value was not reached.
2
The data is defective or not plausible.
3
There is a short circuit or an overvoltage.
4
There is a cable break/short circuit, general error or undervoltage.
5
There is a cable break, general error or overload.
6
There is a short circuit or ground fault.
7
The mechanism does not respond.
8
The frequency is not permitted. The pulse width or period is wrong.
9
The update rate is outside the normal range. As a result, communication
between sensor and control units is defective.
10
The response to an action (rate of change) is outside the normal range.
11
The cause of the error is unknown.
12
The logic in the control unit or in the component is defective.
13
The values of the calibration are outside the value range.
14
Particular instructions are required.
15
The upper limit value has been exceeded.
16
The upper limit value has been exceeded.
17
The lower limit value has not been reached.
18
The lower limit value has not been reached.
19
There is a network/CAN error.
20
The data is not plausible or too high.
21
The data is not plausible or too low.
31
The conditions of the message have been met.
8.16.1.2
Cable break, short circuit
Short circuit to ground