Terminal – menus [Medium Plus/Comfort Plus Electronics]
8
Alarm messages
8.16
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
81
BX001-689
1
Signal line
2
Earth line
If the signal voltage is below the permitted value, short circuit to ground is present.
Possible cause: The cable is damaged and has made contact with the vehicle body.
Cable break
BX001-690
1
Signal line
2
Earth line
If the input signal has not been recorded, there is a broke cable.
Possible cause: The cable is not connected or it is damaged or severed (torn off).
Short circuit
BX001-691
1
Signal line
2
Earth line
There is a connection between the power supply voltage (plus and minus) or the signal voltage
and ground. There is a short circuit.
Possible cause: The cable is damaged and the supply lines to the sensors are connected to
each other.
Содержание 870 HDP
Страница 380: ...FLUFXLW GLDJUDP 1 LJ3DFN EDOHU L 3 LJK 6SHHG 3 ...