Engineering manual - UniSAB III 1.10.8
8/346
001930 en 2021.06
Shutdowns and alarms list with id nos.
......................................... 64
Shutdowns and alarms for screw compressors...................... 64
Shutdowns and alarms for reciprocating compressors ........... 67
Compressor control and surveillance
................................................. 69
Compressor regulation set-up ..................................................... 69
Control mode set-up ........................................................... 69
Regulator set-up ................................................................. 70
Regulation of screw compressors......................................... 70
Capacity PID regulation (outer loop) ..................................... 71
Capacity P regulation (inner loop) ........................................ 72
Vi slide regulation ............................................................... 72
Regulator settings............................................................... 72
Regulation of reciprocating compressors .............................. 76
Set points for regulators ...................................................... 77
User input regulator (Ext. input)............................................ 82
Set point control with user input 1......................................... 83
Capacity control with user input 1 ......................................... 85
Climate compensation......................................................... 86
Limiting functions ....................................................................... 90
Introduction ........................................................................ 90
Standard limiters................................................................. 91
Special limiters ................................................................... 93
Display indications (screw compressors) ............................ 100
Display indications (reciprocating compressors) .................. 101
Compressor control - screw compressors .................................. 102
Start sequence ................................................................. 102
SAB 163 Mk 1 with oil pump .............................................. 102
SAB 110/128/163 Mk 2 without oil pump ............................. 102
SAB 128/163 Mk 2 Booster with oil pump............................ 103
SAB 128HR and 163HR with oil pump ................................ 104
SAB 80 with fitted (mechanical) oil pump ............................ 105
VMY Mk 2 and 2.5 with built-in oil pump.............................. 105
VMY Mk 3 without full flow pump ........................................ 105
FV 19 with oil pump........................................................... 106
FV 24/26 with oil pump ...................................................... 107
SV 24/26 with oil pump...................................................... 107
GSV/RWF with oil pump .................................................... 108
GST with oil pump............................................................. 109
SAB 120 and 151 with oil pump...........................................111
Содержание SABROE Unisab III Control
Страница 1: ...UniSAB III control Version 1 10 8 Engineering manual EN...
Страница 2: ......
Страница 347: ......