XC886/888CLM
Controller Area Network (MultiCAN) Controller
User’s Manual
15-68
V1.3, 2010-02
MultiCAN, V1.0
The Node Port Control Register NPCRx configures the CAN bus transmit/receive ports.
NPCRx can be written only if bit NCRx.CCE is set.
NPCRx (x = 0-1)
Node x Port Control Register
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
LBM
0
RXSEL
r
rw
r
rw
Field
Bits
Type Description
RXSEL
[2:0]
rw
Receive Select
RXSEL selects one out of 8 possible receive inputs.
The CAN receive signal is performed only through the
selected input.
Note: In XC886/888, only specific combinations of
RXSEL are available (see also
LBM
8
rw
Loop-Back Mode
0
Loop-Back Mode is disabled.
1
Loop-Back Mode is enabled. This node is
connected to an internal (virtual) loop-back
CAN bus. All CAN nodes which are in Loop-
Back Mode are connected to this virtual CAN
bus so that they can communicate with each
other internally. The external transmit line is
forced recessive in Loop-Back Mode.
0
[7:3],
[31:9]
r
Reserved
Read as 0; should be written with 0.
*
Содержание XC886CLM
Страница 1: ...User s Manual V1 3 2010 02 Microcontrollers 8 Bit XC886 888CLM 8 Bit Single Chip Microcontroller...
Страница 3: ...User s Manual V1 3 2010 02 Microcontrollers 8 Bit XC886 888CLM 8 Bit Single Chip Microcontroller...
Страница 324: ...XC886 888CLM Serial Interfaces User s Manual 12 52 V1 3 2010 02 Serial Interfaces V 1 0...
Страница 663: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG...