XC886/888CLM
Capture/Compare Unit 6
User’s Manual
14-11
V1.3, 2010-02
CCU6, V 1.0
This mode can be used to introduce a timing-related behavior to a hysteresis controller.
A standard hysteresis controller detects if a value exceeds a limit and switches its output
according to the compare result. Depending on the operating conditions, the switching
frequency and the duty cycle may change constantly.
Figure 14-8
Hysteresis-Like Control Mode
Compare
value
Compare
value
Period value
Period value
0
0
CC6xST
Pin CC6x
(CC6xPS=0,
PSL=0)
Pin COUT6x
(COUT6xPS=1
PSL=0)
T12
T12
Edge-aligned mode
Center-aligned mode
Pin CCPOSx
*