XC886/888CLM
Capture/Compare Unit 6
User’s Manual
14-49
V1.3, 2010-02
CCU6, V 1.0
Field
Bits
Type Description
CC6xSL
(x = 0, 1, 2)
7:0
rwh
Shadow Register for Channel x
Capture/Compare Value Low Byte
In compare mode, the contents of bit field CC6xS
are transferred to the bit field CC6xV during a
shadow transfer. In capture mode, the captured
value of T12 can be read from these registers.
CC6xSRH (x = 0, 1, 2)
Capture/Compare Shadow Register for Channel CC6x High
Reset Value: 00
H
7
6
5
4
3
2
1
0
CC6xSH (x = 0, 1, 2)
rwh
Field
Bits
Type Description
CC6xSH
(x = 0, 1, 2)
7:0
rwh
Shadow Register for Channel x
Capture/Compare Value High Byte
In compare mode, the contents of bit field CC6xS
are transferred to the bit field CC6xV during a
shadow transfer. In capture mode, the captured
value of T12 can be read from these registers.
*