XC886/888CLM
Controller Area Network (MultiCAN) Controller
User’s Manual
15-98
V1.3, 2010-02
MultiCAN, V1.0
V3
7
rw
CAN Data 3 Valid
0
Data in CAN_DATA3 register is not valid for
transmission.
1
Data in CAN_DATA3 register is valid for
transmission.
CAN_ADL
Can Address Register Low
Reset Value: 0000 0000
B
7
6
5
4
3
2
1
0
CA9
CA8
CA7
CA6
CA5
CA4
CA3
CA2
rwh
Field
Bits
Type Description
CAn (n=2 to 9)
n-2
rwh
CAN Address Bit n
CAN_ADH
CAN Address Register High
Reset Value: 0000 0000
B
7
6
5
4
3
2
1
0
0
CA13
CA12
CA11
CA10
r
rwh
rwh
rwh
rwh
Field
Bits
Type Description
CA10
0
rwh
CAN Address Bit 10
CA11
1
rwh
CAN Address Bit 11
CA12
2
rwh
CAN Address Bit 12
CA13
3
rwh
CAN Address Bit 13
0
[7:4]
r
Reserved;
read as 0; should be written with 0.
Field
Bits
Type Description
*
Содержание XC886CLM