XC886/888CLM
Controller Area Network (MultiCAN) Controller
User’s Manual
15-42
V1.3, 2010-02
MultiCAN, V1.0
•
Write the data to the CAN_DATA0/CAN_DATA1/CAN_DATA2/CAN_DATA3
registers.
•
Write the register CAN_ADCON, including setting the valid bit of the data registers
and setting register bit RWEN to 1.
•
The valid data will be written to the MultiCAN kernel only once. Register bit BSY will
become 1.
•
When Register bit BSY becomes 0, the transmission is finished.
Read Process to the MultiCAN Kernel
•
Write the address of the MultiCAN kernel register to the CAN_ADL and CAN_ADH
registers.
•
Write the register CAN_ADCON, setting register bit RWEN to 0.
•
The 32-bit data will be read from the MultiCAN kernel only once. Register bit BSY will
become 1.
•
When register bit BSY becomes 0, the transmission is finished.
•
Read the data from the CAN_DATA0/CAN_DATA1/CAN_DATA2/CAN_DATA3
registers.
Note: The address registers and data registers should be only written/read when register
bit BSY is 0.
*