XC886/888CLM
Capture/Compare Unit 6
User’s Manual
14-81
V1.3, 2010-02
CCU6, V 1.0
T13PM
1
rh
Timer T13 Period-Match Flag
0
A timer T13 period-match has not yet been
detected since this bit has been reset for the last
time.
1
A timer T13 period-match has been detected.
TRPF
2
rh
Trap Flag
The trap flag TRPF will be set by hardware if
TRPPEN = 1 and CTRAP = 0 or by software. If
TRPM2 = 0, bit TRPF is reset by hardware if the input
CTRAP becomes inactive (TRPPEN = 1). If
TRPM2 = 1, bit TRPF must be reset by software in
order to leave the trap state.
0
The trap condition has not been detected.
1
The trap condition has been detected (input
CTRAP has been 0 or by software).
TRPS
3
rh
Trap State
0
The trap state is not active.
1
The trap state is active. Bit TRPS is set while bit
TRPF = 1. It is reset according to the mode
selected in register TRPCTR.
During the trap state, the selected outputs are set to
the passive state. The logic level driven during the
passive state is defined by the corresponding bit in
register PSLR. Bit TRPS = 1 and TRPF = 0 can occur
if the trap condition is no longer active but the selected
synchronization has not yet taken place.
CHE
4
rh
Correct Hall Event
On every valid hall edge, the contents of EXPH are
compared with the pattern on pin CCPOSx and if equal
bit CHE is set.
0
A transition to a correct (=expected) hall event
has not yet been detected since this bit has been
reset for the last time.
1
A transition to a correct (=expected) hall event
has been detected.
Field
Bits
Type Description
*
Содержание XC886CLM
Страница 1: ...User s Manual V1 3 2010 02 Microcontrollers 8 Bit XC886 888CLM 8 Bit Single Chip Microcontroller...
Страница 3: ...User s Manual V1 3 2010 02 Microcontrollers 8 Bit XC886 888CLM 8 Bit Single Chip Microcontroller...
Страница 324: ...XC886 888CLM Serial Interfaces User s Manual 12 52 V1 3 2010 02 Serial Interfaces V 1 0...
Страница 663: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG...