XC886/888CLM
Multiplication/Division Unit
User’s Manual
10-10
V1.3, 2010-02
MDU, V2.1
Field
Bits
Type Description
SCTR
4:0
rw
Shift Counter
The count written to SCTR determines the number of
shifts to be performed during a shift operation.
SLR
5
rw
Shift Direction
0
Selects shift left operation.
1
Selects shift right operation.
0
7:6
rw
Reserved
Should be written with 0. Returns undefined data if
read.
MR4
Shift Output Control Register
Reset Value: 00
H
7
6
5
4
3
2
1
0
0
SCTR
rh
rh
Field
Bits
Type Description
SCTR
4:0
rh
Shift Counter
After a normalize operation, SCTR contains the
number of normalizing shifts performed.
0
7:5
rh
Reserved
Returns undefined data if read.
*