XC886/888CLM
Controller Area Network (MultiCAN) Controller
User’s Manual
15-28
V1.3, 2010-02
MultiCAN, V1.0
context of the message object. Therefore, a message object re-configuration should
consist of the following steps:
1. Clear MSGVAL bit
2. Re-configure the message object while MSGVAL = 0
3. Clear RTSEL bit and set MSGVAL again
RXEN
Bit MOSTATn.RXEN enables a message object for frame reception. A message object
can receive CAN messages from the CAN bus only if RXEN = 1. The MultiCAN module
evaluates RXEN only during receive acceptance filtering. After receive acceptance
filtering, RXEN is ignored and has no further influence on the actual storage of a received
message in a message object.
Bit RXEN enables the “soft phase out” of a message object: after clearing RXEN, a
currently received CAN message for which the message object has won acceptance
filtering is still stored in the message object but for subsequent messages the message
object no longer wins receive acceptance filtering.
RXUPD, NEWDAT and MSGLST
An ongoing frame storage process is indicated by the bit MOSTATn.RXUPD (“Receive
Updating”). RXUPD is set with the start and cleared with the end of a message object
update (which consists of frame storage as well as flag updates).
After storing the received frame (identifier, IDE bit, DLC and the data field for data frames
as well) the bit MOSTATn.NEWDAT (“New Data”) is set. If NEWDAT was already set
before it becomes set again, bit MOSTATn.MSGLST (“Message Lost”) is set to indicate
a data loss condition.
The RXUPD and NEWDAT flags can help to read consistent frame data from the
message object during an ongoing CAN operation. The following steps are
recommended to be executed:
1. Clear NEWDAT bit.
2. Read message content (identifier, data etc.) from the message object.
3. Check that both NEWDAT and RXUPD are cleared. If this is not the case, go back to
step 1.
4. As step 3 was successful, the message object content is consistent, i.e., has not
been updated by the MultiCAN module while reading.
Bits RXUPD, NEWDAT and MSGLST have the same behavior for the reception of data
as well as remote frames.
*
Содержание XC886CLM
Страница 1: ...User s Manual V1 3 2010 02 Microcontrollers 8 Bit XC886 888CLM 8 Bit Single Chip Microcontroller...
Страница 3: ...User s Manual V1 3 2010 02 Microcontrollers 8 Bit XC886 888CLM 8 Bit Single Chip Microcontroller...
Страница 324: ...XC886 888CLM Serial Interfaces User s Manual 12 52 V1 3 2010 02 Serial Interfaces V 1 0...