INDEX VLAN VLAN PORT F/ S/ P VPI VCI FLOW FLOW RX TX
STATE
ID ATTR TYPE TYPE
PARA
-------------------------------------------------------------------------
0 100 common vdl 0/1 /2 - - encap pppoe 6 6
up
1 100 common vdl 0/1 /3 - - encap pppoe 6 6
up
-------------------------------------------------------------------------
Total : 2 (Up/Down : 2/0)
huawei(config)#
stacking label service-port 0 11
huawei(config)#
stacking label service-port 1 12
NOTE
In the actual configuration, the index of the traffic stream may vary according to the number
of traffic streams in the system. You only need to ensure that the actual index corresponds to
the inner VLAN tag.
6.
Save the data.
huawei(config)#
save
l
The procedure for configuring the VLAN ID extension on MA5616_B is as follows:
The configuration procedure of MA5616_B is the same as the configuration procedure of
MA5616_A. The only difference lies in the upstream VLAN ID. Hence, it is not described
here.
----End
Result
After being authenticated by the BRAS, the users on MA5616_A and MA5616_B can access
the Internet.
Two users of the MA5616 can be identified according to one outer VLAN tag. In this manner,
the number of the access user based on one VLAN tag is increased.
Configuration File
Configuration file of MA5616_A
Create a VLAN.
vlan 100 smart
Set the VLAN attribute to stacking VLAN.
vlan attrib 100 stacking
Add an uplink port to the VLAN.
port vlan 100 0/0 1
Add service ports to the VLAN.
service-port 0 vlan 100 vdsl mode ptm 0/1/2 multi-service user-encap pppoe rx-cttr
6
tx-cttr 6
service-port 1 vlan 100 vdsl mode ptm 0/1/3 multi-service user-encap pppoe rx-cttr
SmartAX MA5616 Multi-service Access Module
Configuration Guide
8 Configuration Example of Services on the MA5616
Through GPON Upstream Transmission
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
375