l
If the device is interconnected with the NMS through the GE upstream port in inband
networking mode, the communication port (GE upstream port) must be configured. For
detailed procedure, see
3.1.4 Configuring Inband Management (GE Upstream)
Networking - Inband Networking Mode
As shown in the inband networking in
3.2.1 Configuring the U2000 (Based on SNMPv1)
, the
SNMP protocol is transmitted through the service channel. Service packets and management
packets are transmitted through the same channel. The inband NMS management is implemented
through the upstream port.
l
The MA5616 supports GPON/GE upstream port.
l
A static route is used between the MA5616 and the U2000.
Networking - Outband Networking Mode
As shown in the outband networking in
3.2.1 Configuring the U2000 (Based on SNMPv1)
,
the SNMP protocol is transmitted through the management channel. Service packets and
management packets are transmitted through different channels. The outband NMS management
is implemented through the maintenance network port.
l
The MA5616 supports the local maintenance network port ETH.
l
A static route is used between the MA5616 and the U2000.
Configuration Flowchart
To configure the NMS, see the flowchart for configuring the NMS in
.
Procedure
l
Configuration procedure on the device
1.
Configure the SNMP parameters.
a.
Configure the community names and the access rights.
Run the
snmp-agent community
command to configure the community names
and the access rights.
NOTE
The read community name is
public
. The write community name is
private
.
The read community name and the write community name on the device must be the
same as those configured on the U2000.
huawei(config)#
snmp-agent community read public
huawei(config)#
snmp-agent community write private
b.
(Optional) Set the information about the administrator.
Run the
snmp-agent sys-info
command to set the contact of the SNMP Agent
administrator and the physical position of the device.
Contact of the administrator: HW-075528780808. Physical position of the
device: Shenzhen_China.
huawei(config)#
snmp-agent sys-info contact HW-075528780808
huawei(config)#
snmp-agent sys-info location Shenzhen_China
c.
Set the SNMP version.
Run the
snmp-agent sys-info
command to set the required SNMP version.
SmartAX MA5616 Multi-service Access Module
Configuration Guide
3 Basic Configuration
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
35