Data preparation
Before configuring an xDSL Internet access service, plan the data items as listed in
Table 5-1
Data plan for the xDSL Internet access service
Item
Data
Remarks
MA5616
Access rate
Specify an access rate according to the
user requirement.
Access port
Specify an access port according to the
specific network planning.
VPI/VCI
The VPI/VCI is valid only for the
ATM access and must be the same as
the VPI/VCI of the interconnected
device.
VLAN planning
The VLAN planning must ensure
proper cooperation with the upper-
layer device and thus the upstream
VLAN must be consistent with the
upstream VLAN of the upper-layer
device.
QoS policy
According to the general QoS policy
for the entire network, the priority of
an ordinary Internet access service is
lower than the priority of a voice or
video service.
IP address
The IP address must be consistent with
the IP address of the upper-layer route.
Upper-
layer LAN
switch
The LAN switch transparently
transmits the service packets of the
MA5616 on L2.
The VLAN ID must be consistent with
the VLAN ID of the upstream service
packets of the MA5616.
-
SmartAX MA5616 Multi-service Access Module
Configuration Guide
5 Configuring the xDSL Internet Access Service
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
158