Related Operation
lists the related operation for configuring the dual homing.
Table 7-33
Related operation for configuring the dual homing
To...
Run the Command...
Query the configuration of the SIP
interface
display if-sip attribute
7.8.3 Configuring the Emergency Standalone
This topic describes how to configure the emergency standalone function on the MA5616. When
the MA5616 and the MGC device fail to communicate with each other, the MA5616
independently processes the internal users connecting to the same MG interface; therefore, the
internal users can make calls normally without the control of MGC.
Prerequisites
l
The H.248 protocol must be used in the system.
l
The media IP address must exist in the IP address pool.
l
The voice users must be configured on the MG interface and the users can call each other
successfully.
l
If the device cannot communicate with the MG, run the
system parametres 5
command
to configure the media stream forwarding mode as the mode in which the media stream is
forwarded within the device.
l
The phone number of the MG user is configured to be the same as the phone number on
the MGC.
Context
l
When the MG interface works in the emergency standalone state, only the internal users
on the MG interface can communicate with each other properly.
l
To keep the user phone number in the emergency standalone state consistent with the phone
number in the normal condition, configure the phone number on the MG to be the same as
the phone number on the MGC.
Procedure
Step 1
Run the
mg-software parameter 11 1
command to configure the MG interface to support the
emergency standalone function.
Step 2
Run the
digitmap set inner
command to configure the digitmap for the internal calls.
Step 3
(Optional) Run the
standalone parameters
command to configure the parameters of the
emergency standalone timers.
SmartAX MA5616 Multi-service Access Module
Configuration Guide
7 Configuring the Voice Service
Issue 04 (2011-10-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
312