4
EtherNet/IP with FHPP
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
83
4.2.2
EtherNet/IP connections
The EMCA is integrated into an EtherNet/IP network through the following connections.
Note
The EtherNet/IP interface of the EMCA is intended exclusively for connection to local,
industrial fieldbus networks.
Direct connection to a public telecommunications network is not permissible.
EtherNet/IP, Port 1 [X3]: pin allocation
Socket M12
D-coded
5-pin
Pin
Designation
Description
Shield
1
2
3
4
5
1
TD+
Transmitted data + (
T
ransmit
D
ata)
2
RD+
Received data + (
R
eceive
D
ata)
3
TD-
Transmitted data – (
T
ransmit
D
ata)
4
RD-
Received data – (
R
eceive
D
ata)
5
NC
Not connected
Shield
Screening (
Shield
) (socket housing is connection
to functional earth via RC link)
Tab. 4.2
EtherNet/IP, Port 1 [X3]: pin allocation
EtherNet/IP, Port 2 [X2]: pin allocation
Socket M12
D-coded
5-pin
Pin
Designation
Description
Shield
1
2
3
4
5
1
TD+
Transmitted data + (
T
ransmit
D
ata)
2
RD+
Received data + (
R
eceive
D
ata)
3
TD-
Transmitted data – (
T
ransmit
D
ata)
4
RD-
Received data – (
R
eceive
D
ata)
5
NC
Not connected
Shield
Screening (
Shield
) (socket housing is connection
to functional earth via RC link)
Tab. 4.3
EtherNet/IP, Port 2 [X2]: pin allocation
4.2.3
EtherNet/IP copper cabling
EtherNet/IP cables are 4-wire, screened copper cables. The maximum permissible segment length for
copper cabling is 100 m.
Use only EtherNet/IP-specific cabling for the industrial environment corresponding to
è
EN 61784-5-3:2013-09
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......