8
FHPP standard data (I/O data)
136
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
Status byte 3 (record number/SDIR)
The record number of the current record of the record selection mode is reported back through control
byte 3 (record number).
Status byte 3 (record number) – record selection mode
Bit
DE
EN
Description
B0 … 7
Record num
ber
Record num
ber
Record number of the current record
Tab. 8.16
Status byte 3 – record selection mode
The operating mode and type of setpoint value reference for the positioning mode of the direct mode is
reported back through status byte 3 (SDIR).
Status byte 3 (SDIR) – direct mode
Bit
DE
EN
Description
B0
ABS
absolut/ relat
iv
Abs
olute/
Relative
Positioning mode (CDIR.COM1/2)
= 1:
Setpoint value is relative to the actual/setpoint
position (PNU 524)
è
= 0:
Setpoint value is absolute to the project zero
point.
B1
COM1
Control mode
acknowledg
ment
Co
ntrol
M
ode
Feedback
No.
Bit 2 Bit 1 Control mode
0
0
0
Positioning mode
(Position control)
B2
COM2
1
0
1
Force/torque mode
(Current regulation)
2
1
0
Speed mode
(Speed adjustment)
3
1
1
Reserved
B3
RES
–
–
= 0:
Reserved
B4
VLIM
Geschwindigk
eitsgrenzwert
erreicht
Speed (
V
)
LIM
it reached
Positioning mode (CDIR.COM1/2)
Force/torque mode (CDIR.COM1/2)
= 1:
Speed limit is reached.
= 0:
Speed limit is not reached.
B5
XLIM
Stroke limit
reached
Stroke (
X
)
LIM
it reached
Force/torque mode (CDIR.COM1/2)
Speed mode (CDIR.COM1/2)
= 1:
Stroke limit is reached.
= 0:
Stroke limit is not reached.
B6
RES
–
–
= 0:
Reserved
B7
FUNC
Function feed
back
Func
tion Feed
back
= 0:
Reserved
Tab. 8.17
Status byte 3 – direct mode
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......