C
FHPP parameters (PNU)
272
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
PNU 246
Fault handling 1 (Allowed malfunction handling 1)
Subindex 1 … 255
Class: Array
Data type: uint16
Mappable
Access: rw2
Reading or parameterisation of the malfunction handling for the malfunctions 0 ….254.
Definition of the permitted malfunction handling (bitfield)
è
PNU 238.
Subindex 1
Fault number 0 (Malfunction number 0)
Error response for the malfunction number 0.
Subindex 2
Fault number 1 (Malfunction number 1)
Error response for the malfunction number 1.
Subindex 3 … 255
Fault number 2 … 254 (Malfunction number 2 … 254)
Error responses for the malfunction numbers 2 … 254.
Tab. C.41
PNU 246
PNU 280
Safety status (Safety state)
Subindex 1
Class: Var
Data type: uint8
Mappable
Access: ro
Reading of the enable status of the hardware.
The following enable statuses are required for operation:
Bit
Value
Significance
0
0
STO channels (STO1/STO2) [X6.4/5] = 0 V
1
STO channels (STO1/STO2) [X6.4/5] = 24 V
1
Controller enable via fieldbus
1
Always = 1
Controller enable via digital input + fieldbus
0
ENABLE (controller enable) (CO/EC/EP/PN [X9.4]; DIO [X9.16])
= 0 V
1
ENABLE (controller enable) (CO/EC/EP/PN [X9.4]; DIO [X9.16])
= 24 V
2 … 7
= 1
reserved
Note
Only when Bit1 = 1 can the status be switched to “Ready (SA1)” of the FHPP finite state machine.
1)
Parameterisation of the controller enable via
è
PNU 128 or FCT
Tab. C.42
PNU 280
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......