Error management
Error management makes it possible to parameterise the reaction to diagnostic messages of the EMCA.
These diagnostic messages can be classified as error, warning or information. The reactions to the dia
gnostic messages can be established dependent on the classifications made.
Elimination of the malfunction is described in the corresponding diagnostic message
è
F.2.2
Reactions to messages
Depending on the message, the following reactions can be configured:
Reactions to mes
sages
Description
PNU
Page
Error
(Error)
When an error occurs (SCON.FAULT, B3 = 1), the EMCA
changes to the status “Malfunction recognised (T7)” of the
FHPP finite state machine
è
page 117. Errors always generate
a reaction to the malfunction (S6) that has an effect on the
behaviour of the drive, e.g. stop behaviour, switching off of the
output stage
è
Tab. F.9. Steps required to restore the ready
status:
–
Remedy the cause of the error and then acknowledge the
error (CCON.RESET, B3)
è
–
Reset error (restart/reset)
è
Errors are displayed via the status LED “ERROR” and “CAN
open status”
è
page 371 or description “Integrated drive with
bus interface”, EMCA-EC-SY-....
238
246
Warning
(Warning)
Warnings (SCON.WARN, B2 = 1) have no influence on the be
haviour of the EMCA and do not need to be acknowledged. To
avoid a subsequent error, the cause of the warning must be
eliminated (SCON.WARN, B2 = 0). Warnings are displayed via
the status LED “ERROR”
è
description “Integrated drive with
bus interface”, EMCA-EC-SY-....
238
246
Information
(Information)
Information messages have no influence on the behaviour of
the drive and do not need to be acknowledged.
238
246
Tab. F.8
Reactions to messages
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......