C
FHPP parameters (PNU)
296
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
C.3.17
Project data - direct operation position
PNU 540
Basic value speed (Basic value velocity)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the basic value for speed [SINC/s].
The master transmits a percent value, which is multiplied by the basic value to calculate the final
setpoint speed.
Tab. C.102 PNU 540
PNU 541
Acceleration (Acceleration)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the acceleration [SINC/s
2
].
Tab. C.103 PNU 541
PNU 542
Deceleration (Deceleration)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the deceleration [SINC/s
2
].
Tab. C.104 PNU 542
PNU 543
Jerk acceleration (Jerk acceleration)
Subindex 1
Class: Var
Data type: uint32
Mappable
Access: rw2
Reading or parameterisation of the max. jerk [(SINC/s
3
)/10] during acceleration. The value 0 is inter
preted as max. jerk.
Tab. C.105 PNU 543
PNU 544
Load (Load)
Subindex 1
Class: Var
Data type: uint32
Mappable
Access: rw2
Reading or parameterisation of the load that is moved in addition to the basic load during position
ing.
–
Linear axis: [g]
–
Rotative axis: [kgm
2
* 10
-7
]
Tab. C.106 PNU 544
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......