10
Control via FHPP
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
171
10.6
Teach mode
During teaching, the current position of the drive is taken as the absolute position value. The position
value is stored in the parameterised teach target (PNU 520) during teaching
è
Tab. 10.18. The drive
can be moved to the desired target position as follows:
–
via jogging (JOGP/JOGN)
–
via a positioning task
–
manually by hand (status: “drive blocked” and brake released)
The drive does not have to stand still for teaching. But inaccuracies of several millimetres can result
even at low speeds, due to the usual cycle times of the controller, data transmission and the EMCA.
With teaching, the currently stored position value is always overwritten. Through the
parameter “Store data” (PNU 127.2), the newest position value can be stored in the per
manent memory of the EMCA.
10.6.1
FHPP parameter: Teach mode
The following FHPP parameters are available for teach mode.
Overview: FHPP parameters: teach mode
PNU
Name
Page
400.1
Target record number
520
Teach target
Tab. 10.17 FHPP parameters for the teach mode
Teach target (PNU 520)
is taught
PNU
Page
= 1
Position setpoint value of the record (specification)
PNU 404
= 2
Offset axis zero point
PNU 1010
= 3
Project zero point
PNU 500
= 4
Lower software end position
PNU 501.1
= 5
Upper software end position
PNU 501.2
= 6
Position comparator, min. (lower limit value)
PNU 430
= 7
Position comparator, max. (upper limit value)
PNU 431
1)
The desired record number of the record must be parameterised in the parameter “target record number” (PNU 400.1).
Tab. 10.18 Overview of teach targets
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......