D CANopen
communication
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
341
Error messages
Error code
E0 E1
FCT-
Code
Bit
(Error
register)
Description
8150
h
CAN-ID collision
(CAN-ID collision)
–
8200
h
General protocol error
(Protocol error - generic)
–
8210
h
PDO was received with too short a data length
(PDO not processed due to length error)
–
8220
h
Permitted data length of PDO exceeded
(PDO length exceeded)
–
8500
h
Interpolating positioning mode stopped by controller error
(Interpolated positioning mode stopped while error occured on
control unit)
5
0x4B
8600
h
Standstill monitoring
(Standstill monitoring)
5
0x37
8611
h
Following error
(Following error)
5
0x2F
8612
h
Positive software limit
(Software limit positive)
5
0x11
Negative software limit
(Software limit negative)
0x12
Positive direction locked
(Positive direction locked)
0x13
Negative direction blocked
(Negative direction locked)
0x14
Target position behind negative software end position
(Target position behind negative software limit)
0x29
Target position behind positive software end position
(Target position behind positive software limit)
0x2A
Value range violated
(Value range violated)
0x4C
FF00
h
Internal communication error CPUs
(Internal communication error CPUs)
7
0x03
FF01
h
Invalid hardware
(Non-permitted hardware)
7
0x04
FF02
h
Offset determination for current measurement
(Offset determination for current measurement)
7
0x09
These error messages cannot be sent, as the CAN-bus is not operational. But FCT generates a corresponding FCT-Code.
This error message does not generate an FCT-Code.
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......