F
Diagnostics and fault clearance
388
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
Diagnostic messages and fault clearance
0Ch
Firmware update execution error
Definable as:
F
/-/-
Diagnostic memory: optional
The firmware update has not been properly executed or completed.
Check Ethernet connection between device and PC. Restart device and perform the firmware up
date again. Check whether valid firmware has been selected for the device. The previous firmware
version remains active until the firmware update has been successfully completed. If this error is
still present, the hardware may be defective.
–
Resettable: Cannot be reset, software reset is necessary.
Definable error response(s): A
0Dh
Overcurrent
Definable as:
F
/-/-
Diagnostic memory: always
Short circuit in the motor, lines or brake chopper.
Output stage defective.
Incorrect parameterisation of the current regulator.
Check parameterisation of the current regulator. An incorrectly parameterised current regulator
can generate currents up to the short-circuit limit; as a rule this is clearly noticeable through high
frequency whistling. Inspection with the trace function in FCT (active current actual value).
Error message immediately after connecting to the load supply: Short circuit in the output stage.
The device must be replaced immediately.
Error message only occurs when setting the output stage enable: Short circuit in motor or the
(internal) motor cables. Replace device.
Error occurs only with active brake chopper: Check external braking resistor for short circuit or
insufficient resistance value.
–
Resettable: Cannot be reset, software reset is necessary.
Definable error response(s): A
0Eh
I²t malfunction motor
Definable as:
F
/-/-
Diagnostic memory: always
The I²t limit for the motor is reached. The motor or the drive system may be insufficient for the re
quired task.
Check the layout of the drive system.
Check the mechanics for sluggishness.
Reduce load/dynamic response, longer time delays.
–
Resettable: Error can only be reset after the cause of the error has been eliminated.
Definable error response(s): B,
C
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......