C
FHPP parameters (PNU)
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
291
C.3.12
Project Data – General Project Data
PNU 500
Project zero point (Project zero point)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the point of reference for position values in the application.
Offset of the axis zero point [SINC] to the project zero point.
Tab. C.87
PNU 500
PNU 501
Software end positions (Software position limits)
Subindex 1, 2
Class: Array
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the software end positions [SINC]
è
A setpoint specification (position) outside the software end positions is not permissible and will res
ult in an error. The offset to the axis zero point is entered.
The software end positions are deactivated if both software end positions have the value = 0.
Subindex 1
Lower limit value (Lower limit)
Limit value for the negative software end position (SLN)
Subindex 2
Upper limit value (Upper limit)
Limit value for the positive software end position (SLP)
Tab. C.88
PNU 501
PNU 502
Max. permitted speed (Max. velocity)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the max. permitted speed [SINC/s].
This value limits the speed in all operating modes.
Tab. C.89
PNU 502
PNU 503
Max. permitted acceleration (Max. acceleration)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the max. permitted acceleration [SINC/s
2
].
Tab. C.90
PNU 503
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......