5
Modbus TCP with FHPP
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
99
5.3.9
Read exception status, Function code 0x07 (Read exception status)
The table describes the structure of the “Read exception status, Function code 0x07” command.
Significance
Read exception status request (0x07)
Field
Bytes
Values
Byte no.
Function code
1
0x07
8
Read exception status response (0x07)
Field
Bytes
Values
Byte no.
Function code
1
0x07
8
Output data
1
0x00: no exception (no exception)
0x01 ... 0xFF: Exception status (exception
status)
9
Read exception status exception (0x87)
Field
Bytes
Values
Byte no.
Error code
1
0x87
8
Exception code
1
0x01: illegal function
0x02: illegal data address
0x03: illegal data value
0x04: server device failure
9
Tab. 5.10 Read exception status, Function code 0x07
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......