FHPP parameters (PNU)
270
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
PNU 234
Permitted error response 1 (Permissible error reaction 1)
Subindex 1 … 255
Class: Array
Data type: uint16
Mappable
Access: ro
Reading of the error responses for the faults 0 ….254.
The parameter is implemented as a bitfield. A value of 55 (0x0037) means, for example, that the error
responses A, B, C, E, and F can be parameterised.
For unassigned diagnostic numbers, the value 65535 (0xFFFF) is returned.
Bit
Value
Significance
0
1
A: No deceleration ramp (free run-out)
Output stage is
switched off imme
diately
1
2
B: Quick-stop deceleration ramp (EMERGENCY STOP)
After that, the out
put stage is
switched off
2
4
C: Deceleration ramp (HALT)
3
8
D: End positioning task
4
16
E: Quick-stop deceleration ramp (EMERGENCY STOP)
Output stage re
mains switched on
5
32
F: Deceleration ramp (HALT)
6
64
G: End positioning task
Subindex 1
Fault number 0 (Malfunction number 0)
Error response for the malfunction number 0.
Subindex 2
Fault number 1 (Malfunction number 1)
Error response for the malfunction number 1.
Subindex 3 … 255
Fault number 2 … 254 (Malfunction number 2 … 254)
Error responses for the malfunction numbers 2 … 254.
Tab. C.38
PNU 234
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......