F
Diagnostics and fault clearance
392
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
Diagnostic messages and fault clearance
1Ch
CAN Node Guarding, FB has master control
Definable as:
F
/-/-
Diagnostic memory: optional
No node monitoring telegram received within the parameterised time.
Adjust the remote frame cycle time to the PLC and check the PLC for failure.
Check cabling: cable specification adhered to, cable break, maximum cable length exceeded,
correct terminating resistors, cable screening grounded, all wires connected? Replace the device
to test the setup. If another device works flawlessly with the same wiring, it means the device is
defective.
–
Resettable: Error can only be reset after the cause of the error has been eliminated.
Parameterisable error response(s):
B
, C, E, F
1Dh
CAN bus comm. stopped by master, FB has master
control
Definable as:
F
/-/-
Diagnostic memory: optional
The master has stopped CAN-bus communication.
Check master.
–
Resettable: Error can only be reset after the cause of the error has been eliminated.
Parameterisable error response(s):
B
, C, E, F
1Eh
NetX configuration error
Definable as:
F
/-/-
Diagnostic memory: optional
Invalid configuration of the fieldbus-specific objects. The communication module was not paramet
erised correctly.
Load factory settings over the parameterisation interface.
–
Resettable: Error can be reset immediately.
Definable error response(s): B, C, D, E,
F
, G
1Fh
NetX network error
Definable as:
F
/-/-
Diagnostic memory: optional
An error has occurred in the bus communication with the master. The bus communication has been
interrupted.
Perhaps the network cable is defective or pulled out, or the controller has interrupted the connection.
Check cabling: cable specifications complied with? Broken cable? Maximum cable length ex
ceeded? Cable screening earthed? All wires connected?
Check communication readiness of the higher-order controller (master).
–
Resettable: Error can be reset immediately.
Definable error response(s): E
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......