C
FHPP parameters (PNU)
292
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
C.3.13
Project data – force/torque mode
PNU 510
Stroke limiter (Stroke limit)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the max. permitted displacement (stroke) [SINC] with active force
control.
With active force control, the actual position relative to the start position must not change by more
than the amount specified in this parameter. In this way, you can ensure that the axis will not perform
an uncontrolled movement if force control is activated by mistake (e.g. workpiece missing).
Monitoring can be activated or deactivated via the control bit “Stroke limit value deactivated
(CDIR.XLIM, B5)”.
Tab. C.91
PNU 510
PNU 512
Max. permitted force (Max. force)
Subindex 1
Class: Var
Data type: int32
Mappable
Access: rw2
Reading or parameterisation of the max. current (force) [mA], with which the motor may be operated.
The value is always positive. Internally, this limits the max. “positive” and “negative” current.
Tab. C.92
PNU 512
C.3.14
Project data –teach mode
PNU 520
Teach target (Teach target)
Subindex 1
Class: Var
Data type: uint8
Mappable
Access: rw2
Reading or parameterisation of the Teach memory. With the next teach command, the actual position
is written to the selected memory
è
Value
Significance
0x01 (1)
Teach setpoint position in record
è
PNU 404
0x02 (2)
Axis zero point
è
PNU 1010
0x03 (3)
Project zero point
è
PNU 500
0x04 (4)
Lower software end position
è
PNU 501.1
0x05 (5)
Upper software end position
è
PNU 501.2
0x06 (6)
Position comparator lower limit
è
PNU 430
0x07 (7)
Position comparator upper limit
è
PNU 431
1)
The desired record number must be parameterised via PNU 400.1 “target record number”.
Tab. C.93
PNU 520
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......