Effect
Error
Error code
Error
... is not inter
rupted
If the EMCA is again addressed with the
valid syntax after the error, the upload or
download can be continued.
To cancel the transmission, a stop com
mand must be sent.
Error type 1: is reported in FPCS
17
(0x11) Job cannot be carried out
in the operating status
101
(0x65) Festo: ReqID is not sup
ported
Error type 1: is reported in package ID
1
(0x01) Incorrect sequence of
the received packages
3
(0x03) Formatting of the tele
gram invalid
4
(0x04) Incorrect command se
quence
... is interrup
ted
With error messages sent by the control
ler, transmission is interrupted. In this
case, the user data are not evaluated.
Differentiation between different error
causes is optionally foreseeable on the
controller.
If transmission is interrupted, the data
transmitted to the controller up to then
are discarded. This should also be
planned in the controller.
Error type 2: is reported in package ID
0
(0x00) Error message from the
controller
2
(0x02) Timeout between 2
packages
5
(0x05) Error during reading
6
(0x06) Error during writing
7
(0x07) Dataset received does
not agree with what was
expected
8
(0x08) Error of parameter file
9
(0x09) Access to parameter file
Tab. A.14 Effect of errors on transmission
In case of errors that result in termination of transmission, error code 0x27 is written in
the diagnostic memory. The error must then be acknowledged via the control function
“Reset Fault” or with the FCT.
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......