F
Diagnostics and fault clearance
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
385
F.4
Explanations for the diagnostic messages
The table of diagnostic messages (
è
section F.4.1) contains the following information:
Term
Significance
PNU
Page
No.
Number of the diagnostic message in hexadecimal notation.
Classifiable as ...
F
/W/I = Fault/Warning/Information
è
Indicates which classification is possible for a diagnostic mes
sage. The factory setting is printed in bold (here F). If a classific
ation is not possible, this is indicated by dashes.
Example: “F/–/–” means that the diagnostic message can only
be classified as a fault.
238
246
Diagnostic
memory
Indicates whether an entry is always made in the diagnostic
memory, or whether this can be parameterised in FCT (always/
optional).
238
246
Acknowledgeab
ility
Information on an error’s ability to be acknowledged:
–
Acknowledge error: acknowledgement via Acknowledge
malfunction (CCON.RESET, B3). Further options
è
–
–
Reset non-acknowledgeable errors: restart via the paramet
er “Reset device” (PNU 127.3, value = 10
h
) further options
è
127.3
Parameterisable
error response(s)
For every diagnostic message, provides the parameterisable
error response as code letters (A to G)
è
Tab. F.14. Code letters
for the factory response settings are printed in bold.
234
242
1)
Only available in the FCT or web server
2)
Permitted values (bit mask)
3)
Current values
Tab. F.13
Explanations of the diagnostic messages
Code letters for the parameterisable error response(s)
A
Free run-out – no deceleration ramp
Output stage
is switched off
immediately
B
Quick-stop deceleration – quick-stop deceleration ramp
After that, the
output stage is
switched off
C
Deceleration record – deceleration ramp of the current positioning task
D
End record – execute the positioning task to the end until Motion complete (MC)
E
Quick-stop deceleration – quick-stop deceleration ramp
Output stage
remains
switched on
F
Deceleration record – deceleration ramp of the current positioning task
G
End record – execute the positioning task to the end until Motion complete (MC)
Tab. F.14
Possible error responses (can be parameterised)
Содержание EMCA-EC-67 CO Series
Страница 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Страница 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Страница 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Страница 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Страница 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Страница 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Страница 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Страница 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Страница 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Страница 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Страница 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Страница 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Страница 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Страница 415: ......