Commissioning
111
• 1st use
• Ri GSCS (only pH)
1st use:
Indicates when the sensor was
connected to a transmitter for the first time.
Ri GSCS:
Displays the current membrane
resistance.
Sensor info
Application
• Max. rng.
• Min. rng.
• Max. temp.
• Min. temp.
Max. rng.:
Maximum measured value in the
sensor application range
Min. rng.:
Minimum measured value in the
sensor application range
Max. temp.:
Maximum temperature in the
sensor application range
Min. temp.:
Minimum temperature in the
sensor application range
Order data
• Order Code
• OVSN
• Check date
Order code:
Order code of the sensor
OVSN:
Overall serial number of the sensor
Check date:
Indicates when the factory test of
the sensor was carried out.
Service
Service diagnosis
Options
• Factory reset
• Simulation
• Instrument check
• DAT download
• Set up 2
• Instrument version
• Topcal
• Chemoclean
• Reset count
Factory reset:
Various data groups can be
reset to the factory setting.
Simulation:
The behavior of the transmitter
can be simulated after a number of parameters
have been entered.
Instrument check:
The instrument functions
(display, keys,...) can be tested individually.
DAT download:
Copy data from/into the
DAT module.
Set up 2:
ISFET values and SCS values
Instrument version:
Device-internal data, e.g.
the serial number, can be queried.
Topcal S:
Test programs, inputs, hardware.
Chemoclean
(only if the complete
Chemoclean function is activated): Test
programs, inputs, hardware.
Reset count:
Counter for the number of resets
and write access
Factory reset
Set default
Options
• Abort
• Only start-up data
• Only calibration data
• Complete reset
• CPC data
• Service data
• Operation log
• Error log
• Calibration log
Here you select the data which you wish to
reset to the factory settings.
!
Note!
Danger of data loss. Selecting a point and
confirming with
F
deletes the settings you
made in this area! Pressing Cancel leaves this
field without changing the values.
Only calibration data:
All the data saved
with calibrations such as zero point, slope, and
offset.
Only start-up data:
The remaining data to be
set
Complete reset:
Calibration data + setting
data
CPC data:
Topcal configuration, e.g. cycles of
cleaning and calibration programs
Service data:
All data + logs + reset counters
!
Note!
Service data / logbooks:
These functions are only for authorized service
personnel. The service code is required.
You can request the service code from
Hauser.
Function
Options
Info