Appendix
167
a0005017-en
CAL
Window info
calibration type
(selected in:PARAM\
Set up 1\Calibration\
Manual calibration):
Cal with enter
spec. buffer:
For cal with manual
buffer:
For calibration with
buffer table /
auto buffer recogn.
Window info calibra-
tion type
(selected in:PARAM\
Set up 1\Calibration\
Manual calibration):
for calibration with
enter data abs.:
For calibration with
calibration abs.:
Window info calibra-
tion type
(selected in:PARAM\
Set up 1\Calibration\
Manual calibration):
(for calibration with
enter data abs. and
with calibration abs.
see above)
For calibration with
calibration rel.:
For calibration with
enter data rel.:
Calibration
Accept
Reject
Recalibrate
Stability check
buffer 1
If stable:
press E
Stability check
buffer 2
If stable:
press E
Note:
Voltage range
too small
Data input:
Zero point
07.00pH
(-2.00...16.00pH)
ISFET:
curr.value(-/+500mV)
Enter temperature
at which zero point
and slope have
been determined.
025.0°C
(-20.0...150.0°C)
Edit slope
57.19mV/pH
(5.00...99.00mV/pH)
Calibration
Accept
Reject
Repeat calibration
Calibration
Accept
Reject
Recalibrate
Calibration
Accept
Reject
Recalibrate
Note:
Electrode
submersed?
Note:
Electrode
submersed?
Note:
Electrode
submersed?
Note:
Electrode
submersed?
Note:
Electrode
submersed?
Edit buffer 2
Temp: 25.0°C
07.00 pH
(–2.00...16.00pH)
Identified buffers:
(or calibration end)
Buffer 1:
Buffer 2:
Buffer type:E+H
Electrode info:
Zero point
Condition
Slope
Condition
Electrode condition
Electrode 1
good
Note: Start
1st buffer
Immerse electrode
in buffer 1
Electrode condition
Electrode
good
Edit buffer 1
Temp: 25.0°C
07.00 pH
(–2.00...16.00pH)
Note:
Calibration result
invalid-->
Reject
Recalibrate
Note:
Calibration result
invalid-->
Reject
Recalibrate
Note: Start
1st buffer
Immerse electrode
in buffer 1
Note: Start
1st buffer
Submerse electrode
in buffer
Note: Start
1st buffer
Submerse electrode
in buffer
Enter al. points
c
1:0...30%:
20%
1: Voltage:
0600 mV
2: 70...100%: 80%
2: Voltage:
-0600mV
Note: Start
2nd buffer
Submerse electrode
in buffer
Note: Start
2nd buffer
Immerse electrode
in buffer 2
Note: Start
2nd buffer
Immerse electrode
in buffer 2
Edit buffer temp.
(only MTC)
025.0°C
(-20.0...150.0°C)
Edit buffer temp.
(only MTC)
025.0°C
(-20.0...150.0°C)
Enter offset
0000mV
(-1500...1500.0mV)
Enter buffer
0225mV
(-1500...1500mV)
Enter buffer 2
10%
(0...30%)
Calibration info
electrode
Offset
0000mV
good
Note:
Calibration result
not valid
If you press the MEAS
key, a message will
appear asking if you
want to abort the
calibration.
= Code entry required
Sensor mode pH:
Sensor mode Redox abs. (mV):
Sensor mode Redox rel. (%):
Stability check
buffer 1
If stable:
press E
Stability check
buffer 2
If stable:
press E
Stability check
buffer 1
If stable:
press E
Stability check
buffer 2
If stable:
press E
Calibration
Accept
Reject
Recalibrate
Note:
Electrode
submersed?
Note:
Electrode
submersed?
Stability check
buffer 1
If stable:
press E
Enter buffer
10%
(0...30%)