Appendix
162
a0005009-en
PARAM
Data log 1/2
Meas.
value pH/Redox K1
Function
on
Display range
Min 2.00pH/-500mV
Max12.00pH/500mV
(-2...16pH/
-1500...1500mV)
PCS time
PCS K1
off
Select
Data log
Check
Controller
configuration
Limit functions
Controller quick
adjustment
Select
Data log
Measuring interval
Data log 1 /
Data log 2
DataLog View 1/2
Enter
measuring interval
00005s
(2 … 36000s)
SCS mode
SCS K1
off
SCS Ref. K1
off
View of logged
measuring values of
DataLog 1 resp. 2
with date and time
PARAM
Set up 1
Manual operation
First start up
Set up 2
»Return field«:
press the PARAM
key to return to
the highlighted
fields.
= Code entry required
Back to
return field
Back to
return field
Back to
return field
Back to
return field
Back to
return field
Back to
return field
With segmented:
Control point
Start neutral zone
End neutral zone
Optimisation point 1/2
Control point 1/2
Current output 2:
Assign
100% acid dosing
0 mA
20 mA
Relay selection
Pulse frequency:
Relay:
n.c.
Max. pulse
frequency 120/min.
Process speed
(only linear)
Slow
Standard
Fast
User
Relay selection
Pulse frequency:
Relay:
n.c.
Max. pulse
frequency 120/min.
Configuration of
external hardware:
Actuator
Characteristic
Select characteristic
type:
linear
segmented
Controller
Function:
off
Setpoint:
07.00pH
Curr. value: 07.00pH
Selection Control
(when curr.
output defined)
2 outputs
(=2 relays)
1 output
(= current output2)
Control using
Pulse length
Pulse frequency
Current output
With linear:
Control point
Start neutral zone
End neutral zone
Kr 1
Kr 2 (only 2-sided)
Control
Base: I-length
Acid: I-length
Dosing via
Current output 2:
0 ... 20 mA
4 ... 20 mA
batch/inline
1-sided
batch/inline
2-sided
Selection of process
type:
batch 1-s. base
batch 1-s. acid
batch2-sided
inline 1-s. base ......
Activating Controller
function
(contr. must have been
configured)
off
on
Parameter:
Kr1:01.00pH(only lin.)
Kr2:01.00pH(only lin.)
Tn1:
000.0
Tn2:
000.0
Tv1:
000.0
Tv2:
000.0
Back to
return field
Configuration
LVS 1/2/3/4/5:
Switch-on delay: 0 s
Switch-off delay: 0 s
Alarm
threshold: pH 16
Select for
configuration:
Limit value 1
...
Limit value 5
Configuration
LVS 1/2/3/4/5
Function: off
Assign.: pH circuit 1
Switch-on pt.: pH 16
Switch-off pt.: pH 16
Relay selection
Pulse length:
Relay:
n.c.
Period:
000.0s
tE min:
000.0s
Relay selection
Pulse length:
Relay:
n.c.
Period:
000.0s
tE min:
000.0s
Dosing via
Current output 2:
0 ... 20 mA
4 ... 20 mA