Appendix
158
a0005013-en
PARAM
Edit service code
0000
(0...9997)
Edit specialist
code
0000
(0...9997)
Edit Damping
pH/ORP:
00s
Temperature:
00s
(0...30s)
Display format
pH
pH 00.0
(only pH)
00.00
Select temperature
display
° F
°C
Select
Current output conf.
2
Current output 1
Current output
Relay function
NAMUR
off
Relay 1:
free
Relay 2:
free
.....
Relay 5:
free
Select
Current output 1
Temperature Input 1
pH/mV Input 1
Select Current out.2
pH/mV Input 1
cont. controller
Temp. Input 1
Select NAMUR
NC contact
NO contact
Select Limit
NC contact
NO contact
Note if selection is
changed:
Caution! Conf. will
be reset.
(Cancel with
PARAM)
Select Controller
NC contact
NO contact
Select Failure
configuration
Active pulse
Active on
Note field
Chemoclean is
always NO.
(if CCC and CCW
selected)
Select
Output range 1/2
0 … 20 mA
4 … 20 mA
Warning if
»Min« is selected
for current range
0...20mA
Select characteristic
1/2
table
linear
Edit number
0/4 mA: 02.00pH
(000.0°C)
20 mA: 12.00pH
(100.0°C)
Enter number
of table points
01
(1...10)
Select
Temp.comp.
process (only pH)
Temp.comp.
sensor
Select temp. comp.
MTC
MTC + Temp.
(only pH)
ATC Input 1
Edit MTC temp.
°C
(only pH,MTC)
(-20.0...150.0°C)
025.0
Temperature
measurement
on
(only Redox)
off
Temp.sensor
Pt 100
NTC 30
no
Pt 1000
Actual temp. value
for Offset
25.0°C
(20.0...30.0°C)
Edit Offset
0.0°C
(-5.0...5.0°C)
Select
Create table
Reference
temperature
Select table
Select medium K1
Medium 1
Medium 2
Medium 3
no
Select medium
Medium 2
Medium 3
Medium 1
Reference
temperature in
laboratory meas.
25.0°C
(-20.0...150.0°C)
Select
Sensor input
Display
Bus configuration
Access codes
Current output
Relays
Temperature
(only communication)
(not available with
Profibus)
Select operating
mode
Redox/ORP: mV
Redox/ORP: %
pH
Edit tag number
(0...9; A...Z)
Select electrode
type 1
Glass electrode 4.6
Antimony
ISFET
(only pH)
Glass electrode 7.0
Select
Sensor ground
no solution ground
solution ground
Date+time
Weekday
Day
30
Month
04
Year
01
Time
12:00
Mo
Edit Contrast
with + and - keys
Select language
English
GB
Deutsch
D
»Return field«:
press the PARAM
key to return to
these highlighted
fields.
= Code entry required
Back to
return field
Back to
return field
Edit pairs
°C
pH
000.0
00.00
Query
Ok
Delete pair
(then back to the
edit pairs)
Note field
Table status
invalid table
--> back
Valid table
--> to return field
Edit table points
02
(2...10)
Back to
return field
Back to
return field
PARAM
Set up 2
Manual operation
First set up
Set up 1
Enter
bus address
0
(0...15)
(only communication)
Display of meas.
point designation
(tag number)
- - - - - - - -
(only communication)