98
Xi=25
Switch input control mode to torque control mode
When the terminal is on, the present control mode is switched to torque control
mode. Its function is equivalent to F0-03=1. After the terminal is off, inverter
returns the previous input control mode automatically.
When the corresponding function terminals of Xi=24/25 are on simultaneously,
terminal of Xi=24 is prior to terminal of Xi=25. If it is not set as SVC1,
F0-02≠3
,
it cannot be switched to torque control.
Xi=26
Not Used
Xi=27
Switch speed input setting mode to primary speed setting mode
In speed control mode, if the terminal is on, and then integrated speed input mode is
switched to primary speed setting mode. After the terminal is off, inverter returns
the previous input mode automatically. It is equivalent to setting F9-03 ones place=0
when it is on.
Xi=28
Switch speed input setting mode to auxiliary speed setting mode
In speed control mode, if the terminal is on, then the speed input setting mode is
switched to auxiliary speed setting mode. Its function is equivalent to setting F9-03
ones place =1. After the terminal is off, inverter returns the previous setting mode
automatically.
Xi=29
Switch primary speed setting mode to regular speed setting mode
In speed control mode, if the terminal is on, then the primary speed setting mode is
switched to regular speed setting mode. Its function is equivalent to setting F0-26=0.
After the terminal is off, inverter returns the previous setting mode automatically.
Xi=30
Switch regular speed input setting mode to numeric speed input setting mode
In regular speed control mode, if the terminal is on, then the present regular speed
setting mode of F0-06 is switched to the numeric speed input setting mode. Its
function is equivalent to setting F0-06=0. After the terminal is off, inverter returns
the previous setting mode automatically.
Xi=31
Switch jog input setting mode to jog numeric speed input setting mode
In regular speed control mode, if the terminal is on, then the present jog speed
setting mode is switched to jog numeric speed input setting mode. Its function is
equivalent to setting the tens place of F9-03=0. After the terminal is off, inverter
returns the previous setting mode automatically.
Xi=32
~
34
Not used
Xi=35
Switch regular torque input setting to numeric torque input setting
In regular speed control mode, if the terminal is on, then the present regular torque
setting mode is switched to the numeric torque input. Its function is equivalent to
setting F5-11=0. After the terminal is off, inverter returns the previous setting mode
automatically.
Xi=36
Not used
Xi=37
PID positive/negative function switch
In the process of process PID control operation, if the input signal of the function