8.9.9
Zero Frequency Parameter
No.
Function
Range
Unit Default Type
F7-31
Zero Frequency Brake Current 100.00~500.00
%
100.00
〇
If F5-27=0, F7-31 is to set zero speed holding torque. The setting value of F7-31 is the
percentage of idling current.
8.10
F8 Group: Input/Output Bias
8.10.1
Options of Analog Setting Signal
No.
Function
Range
Unit
Default
Type
F8-00
Voltage /Current
Input Options
Ones place: VS voltage options
0: 0~10V
1: 2~10V
Tens place: VF voltage options
0: 0~10V
1: 2~10V
Hundreds place: IS current options
0: 4~20mA
1: 0~20mA
Thousands place: IF current options
0: 4~20mA
1: 0~20mA
0000
〇
Ones place: VS voltage options
F8-00 ones place=
0, the linear range of terminal VS voltage input: 0
~
10V=0
~
100%. See
Figure 7-25.
F8-00 ones place=
1, the linear range of terminal VS voltage input: 2
~
10V=0
~
100%. See
Figure 7-26.
Tens place: VF voltage options
F8-00 tens place=0,
the linear range of terminal VF voltage input: 0
~
10V=0
~
100%. See
Figure 7-25.
F8-00 tens place=
1, the linear range of terminal VF voltage input: 2
~
10V=0
~
100%. See
Figure 7-26.
Hundreds place: IS current options
F8-00 hundreds place=0,
the linear range of terminal IS voltage input: 4
~
20mA=0
~
100%.
See Figure 7-27.
F8-00 hundreds place=1,
the linear range of terminal IS voltage input: 0
~
20mA=0
~
100%.
See Figure 7-28.
Thousands place: IF current options
F8-00 thousands place=0,
the linear range of terminal IS voltage input: 4
~
20mA=0
~
100%. See Figure 7-27.
F8-00 thousands place=1,
the linear range of terminal IS voltage input: 0
~
20mA=0
~
100%. See Figure 7-28.