F9-04=1 Wobbulation Mode
If F0-26 is selected as special speed setting mode, inverter will run in wobbulation mode. See
7.8 for wobbulation running mode.
F9-04=2 Stepping Mode 0
The starting frequency is F0-07 primary numeric frequency setting. When terminal
UP/DOWN is on, the starting frequency will rise/drop as per the present effective
acceleration/deceleration time. When terminal UP/DOWN is off, the starting frequency will
remain present output frequency unchanged.In stopping state, the setting frequency is
changed as F0-07.
F9-04=3 Stepping Mode 1
Starting frequency is 0Hz. When terminal UP/DOWN is on, the starting frequency will
rise/drop as per the present effective acceleration/deceleration time. When terminal
UP/DOWN is off, the starting frequency will remain present output frequency unchanged.
F9-04=4 Stepping Mode 2
Starting frequency is F0-07 primary numeric frequency setting. When terminal UP/DOWN is
on, the starting frequency will rise/drop as per F9-07 UP/DOWN frequency rate. When
terminal UP/DOWN is off, the starting frequency will remain present output frequency
unchanged.In stopping state, the setting frequency is changed as F0-07.
F9-04=5 Stepping Mode 3
Starting frequency is 0Hz. When terminal UP/DOWN is on, the starting frequency will
rise/drop as per F9-07 UP/DOWN frequency rate. When terminal UP/DOWN is off, the
starting frequency will remain present output frequency unchanged.
F9-04=6 Stepping Mode 4
Starting frequency is F0-07 primary numeric frequency setting. When terminal UP/DOWN is
on, the starting frequency will rise/drop as per F9-07 UP/DOWN frequency rate. When
terminal UP/DOWN is off, the setting frequency will reset as F0-07 primary numeric
frequency setting.
F9-04=7 Stepping Mode 5
The starting frequency is primary numeric frequency setting of F0-07, when UP/DOWN
terminal is ON, the starting frequency rises/falls as per UP/DOWN frequency ratio of F9-07;
when UP/DOWN terminal is off, the setting frequency follows the real time output frequency
without change.
1.
Terminal UP/DOWN is set by multi-function terminal program. For instance: if
set F2-03=13, and F2-04=14, the X4 is terminal UP, and X5 is terminal DOWN.
2.
Present effective acceleration/deceleration time can be defined by the status of
acceleration/deceleration time terminals set by F2-00
~
F2-06. If acceleration/deceleration
time terminals are OFF, the present effective acceleration/deceleration time will be defined
by F9-05 and F0-10.