User Manual
EM303B General Purpose Inverter
62
6.2.6
F5 Group: General Parameters of Vector Control
No.
Function
Range
Unit
Default
Type S/N
F5-00
Speed Proportional Gain ASR_P1 0.00
~
100.00
%
15.00
●
160
F5-01
Speed Integral Time ASR_Ti1
0.00
~
30.00 0.00: No
integration
S
0.50
●
161
F5-02
Speed Differential Time ASR_Td1 0.00
~
10.00
mS
0.00
●
162
F5-03
Speed Proportional Gain ASR_P2 0.00
~
100.00
%
12.00
●
163
F5-04
Speed IntegralTime ASR_Ti2
0.00
~
30.00 0.00: No
integration
S
0.50
●
164
F5-05
Switching Frequency 0
0.00
~
Switching Frequency 1
Hz
5.00
〇
165
F5-06
Switching Frequency 1
Switching Frequency 0
~
Fmax Hz
10.00
〇
166
F5-07
Torque Current Acceleration Time 0.000
~
30.000
S
0.040
●
167
F5-08
Torque Current Deceleration Time 0.000
~
30.000
S
0.040
●
178
F5-09
Power Torque Current Limit
80.00
~
250.00
%
165.00
●
169
F5-10
Brake Torque Current Limit
80.00
~
250.00
%
165.00
●
170
F5-11
Regular Torque Setting
0: Primary Numeric Torque
Setting
1: VP
2: VS
3: IS
4: VF
5: IF
6: Not used
7: K1*VP+K2*(K3*VS+
K4*IS+K5*VF+K6*IF-K8*5V
)
0
〇
171
F5-12
Primary Numeric Torque Current 0.00
~
Maximum torque
%
0.00
●
172
F5-13
Torque Direction
0: Positive Torque
1: Negative Torque
0
●
173
F5-14
Upper Limit Frequency Limiting
of Torque
0: Upper Limit Frequency
1: VS* Upper Limit Frequency
2: IS*Upper Limit Frequency
3: VF*Upper Limit Frequency
4: IF*Upper Limit Frequency
0
〇
174
F5-15
Static friction compensation
coefficient
0.00
~
150.00
%
0
●
175
F5-16
Not Used
176
F5-17
Static friction acting cut-off
frequency
0.00
~
50.00
Hz
2.00
〇
177
F5-18
~
F5-19
Not Used
178
~
179
F5-20
Gain of VVF Excitation Current
0
~
60000
0
●
180