User Manual
EM303B General Purpose Inverter
76
Range
FC-13
Energy Saving Delay
Start Time
0.01
~
60.00
S
0.50
〇
397
FC-14
Energy Saving Permitted
Range
60.00
~
100.00
% 80.00
〇
398
FC-15
Output Voltage
0.00
~
100.00
% 100.00
●
399
FC-16
Brake Duty Ratio
5.00
~
100.00
% 80.00
〇
400
No.
Function
Range
Unit Default Type S/N
FC-17
Over-modulation
Coefficient
1.00
~
1.10
1.05
●
401
FC-18
Voltage Control
Ones place: AVR control
0: Disabled
1: Enabled
2: Auto-AVR
Tens place: AVR limit control
0: Limit disabled
1: Limit enabled
Hundreds place: Not used
001
〇
402
FC-19
Overvoltage Protection
Control
Ones place: Not Used
Tens Place: Dynamic brake options
0: Braking resistor disabled
1: Braking resistor is enabled in operation
2: Braking resistor is enabledat power-on
Hundreds place: Not Used
Thousands place:
Voltage stall protection mode
0.Void
1.Under voltage stall effective
2.Over voltage stall effective
3.Both under voltage stall and over voltage
stall effective
2000
〇
403
FC-20
Voltage at Overvoltage
Stall
120.00
~
140.00
% 130.00
〇
404
FC-21
Overcurrent Stall
Proportion Gain IKp
0.00
~
100.00
0.10
〇
405
FC-22
Overvoltage Stall
Proportion Gain VKp
0.00~100.00
3.00
〇
406
FC-23
Overvoltage Integral
Time VTi
0.000~10.000, 0.000: No integration
S
0.300
〇
407
FC-24
Fault Retry Control
Ones place: Fault retry times
0: Fault retry prohibited
1~3: Fault retry for 1, 2, and 3 times
4: Unlimited fault retry
Tens place:
In fault retry, fault output terminals will be
0: Off 1: On
00
〇
408
FC-25
Fault Retry Timelag
0.01
~
30.00
S
0.50
〇
409
FC-26
No Fault Timelag
0.01
~
30.00
S
10.00
〇
410