79
0
:
VF is on at high level input
1
:
VF is on at low level input
Thousands place: Input terminal IF
0: IF is on at high level input
1: IF is onat low level input
FE-06
Output Signal Type
Ones place: Y1 output type
0: Level signal
1: Pulse signal
Tens place: Y2 output type
0: Level signal
1: Pulse signal
Hundreds place: R1 output type
0: Level signal
1: Pulse signal
000
〇
454
FE-07
Terminal Output Logic
Options
Ones place: Y1 output logic options
0: Positive logic
1: Negative logic
Tens place: Y2 output logic options
0: Positive logic
1: Negative logic
Hundreds place: R1 output logic options
0: Positive logic
1: Negative logic
000
〇
455
FE-08
Virtual Terminal Options
Ones place: Terminals Y1/Y2/R1
0: Actual output terminal
1: Virtual output terminal
Tens place:
Multi-function Input Terminal Xi
0: Actual output terminal
1: Virtual output terminal
Hundreds place:
Numeric terminal VS/IS/VF/IF
0: Actual output terminal
1: Virtual output terminal
000
〇
456
FE-09
Terminal Y1 Delay Time
0.0
~
600.0
S
0.0
〇
457
FE-10
Terminal Y1 Pulse Width
0.0
~
600.0
S
5.0
〇
458
FE-11
Terminal Y2 Delay Time
0.0
~
600.0
S
0.0
〇
459
FE-12
Terminal Y2 Pulse Width 0.0
~
600.0
S
5.0
〇
460
FE-13
Terminal R1Delay Time
0.0
~
600.0
S
0.0
〇
461
FE-14
Terminal R1 Pulse Width
0.0
~
600.0
S
5.0
〇
462
FE-15
~
FE-19
Not Used
463
~
467
FE-20
SC
and
EMC
Faults Display
0
:
SC
Drive failure
1
:
EMC
Environment failure
0
X
468
FE-21
SlU
and
SOFT
Faults Display 0
:
SlU
Stable undervoltage fault
0
X
469